The intersection controller is a device that regulates the traffic flow at signalized intersections and controls the flow of lamps. Thanks to the program defined in the device, the red-green times and the order in which the lights will turn on are determined.
Maestro control devices have TS-EN 50556 quality certificate. It is produced as 4 groups, 8 groups, 12 groups, 16 groups, 20 groups, 24 groups and 32 groups. The 4 groups of devices are mostly known as pedestrian devices. The number of groups is determined by the number of traffic lights at the intersection and their operation at different times. It can be programmed easily thanks to bluetooth and usb. There are two different user faces. These user faces were created with both experienced and new users in mind. There are 2 USB connections for external connections.
Thanks to the extra GPS module that you can add to the controller, a green wave system can be established and synchronized operation between intersections can be achieved. With the central management system to be installed in institutions, you can control the intersection at any time and see the possible problem. This gives you an advantage for quick resolution of problems.
Technicial Specifications
Product Types and Codes:
SN-06-01-100 : 4 gr Maestro Pedestrian Controller
SN-06-01-101 : 8 gr Maestro Junction Controller
SN-06-01-102 : 12 gr Maestro Junction Controller
SN-06-01-103 : 16 gr Maestro Junction Controller
SN-06-01-104 : 20 gr Maestro Junction Controller
SN-06-01-105 : 24 gr Maestro Junction Controller
SN-06-01-106 : 32 gr Maestro Junction Control Device
Turkish Standards Institute (TSE) approval,
Microcontroller-based modular structure,
Easy programming via Bluetooth or USB,
Maximum 32 signal groups, 32 loop detectors and 32 isolated inputs. Safe signaling with sensitive lamp current and voltage controls 4, 8, 12, 16, 20, 24, 28 and 32 group possibilities Ethernet, GPRS and SMS remote connection options,
2 separate programming interfaces for new and experienced users,
Suitability of all entrances for counting and occupancy measurement
2 USB ports for external connections (Computer, GSM, GPS etc.)
16 different phases can be defined and 16 signal plans can be created with the defined phases.
Ability to define 48 steps and create 16 signal sequences using the defined steps
Logical function blocks for the Traffic Adaptive operating mode
Opening and closing sequences
Simulating signal schemes without using traffic signal exits to avoid unsafe or faulty signaling
Normal and fault condition flash modes, flash colors and frequencies
Certificates: TS EN 50556, HD 638